QUICK INFO
Use this screen to enable and disable boost control correction parameters
CONTROL OPTIONS
Feedback
OFF = open loop boost control with solenoid duty cycle parameters
ON = closed loop boost control with boost target parameters
RPM
ON = adjust solenoid duty cycle or target boost pressure versus engine rpm
Gear
ON = adjust solenoid duty cycle or target boost pressure versus selected gear
Speed
ON = adjust solenoid duty cycle or target boost pressure versus vehicle speed
Throttle
ON = adjust solenoid duty cycle or target boost pressure versus engine throttle position
Air temp
ON = adjust solenoid duty cycle or target boost pressure versus intake air temperature
BUTTON FUNCTIONS
- UP - Select next parameter up.
- DOWN - Selected next parameter down.
- LEFT - Go to previous screen.
- RIGHT - Go to next screen.
- ENTER - Switch parameter status from ON to OFF and vice versa.