4.2 Control Options Enable

TUNING ›› MENU STRUCTURE ›› 4. Setup Control ››
Parent Previous Next

QUICK INFO

Use this screen to enable and disable boost control correction parameters







CONTROL OPTIONS


Feedback

OFF = open loop boost control with solenoid duty cycle parameters

ON =   closed loop boost control with boost target parameters


RPM

ON = adjust solenoid duty cycle or target boost pressure versus engine rpm


Gear

ON = adjust solenoid duty cycle or target boost pressure versus selected gear


Speed

ON = adjust solenoid duty cycle or target boost pressure versus vehicle speed


Throttle

ON = adjust solenoid duty cycle or target boost pressure versus engine throttle position


Air temp

ON = adjust solenoid duty cycle or target boost pressure versus intake air temperature


BUTTON FUNCTIONS


- UP -                        Select next parameter up.

- DOWN -                Selected next parameter down.

- LEFT -                Go to previous screen.

- RIGHT -                Go to next screen.

- ENTER -                Switch parameter status from ON to OFF and vice versa.