Controlling the SDM AUX outputs from the ecu

 The requirements for this function to work are:
     a) The Syvecs CAN Datastream ID for sending the control is 0x612.
     b) The 4th parameter of this message must be set to "pduCtl0102(U)".
     c) The message frequency must be at least 5Hz.
     d) The desired function in IO Configuration\Pin Assignments must be set to X PDU CONTROL 01: PDUCTL/01 for AUX1 or /02 for AUX2
 
1) Place the pduCtl0102(U) parameter in the Syvecs datastream.
 
 
2) Configure the reception of the data from the SDM. In the example above the AUX1 status is sent in byte 6 of message 19 and AUX2 in byte 7 of message19
Message 19 has id 0x612
 
3) In the AUX Outputs configuration setup the AUX conditions in the following way. The example is for AUX1
Enable the AUX output, set your label, enable the first condition when the AUX1 SYV parameter received from can is larger than 0.