DTA S Series

 
WIRING
S40 ecu:
SDM-500 pin 5 CAN1 HI   yellow  -------------> S40 pin 16 CAN H
SDM-500 pin 4 CAN1 LO  blue     -------------> S40 pin 17 CAN L
http://www.dtafast.co.uk/Downloads/Wiring_Diagrams/S40%20Wiring%20Diagram.pdf
 
S60 ecu:
SDM-500 pin 5 CAN1 HI   yellow  -------------> S60 pin 26 CAN H on plug with two key-ways
SDM-500 pin 4 CAN1 LO  blue     -------------> S60 pin 28 CAN L on plug with two key-ways
http://www.dtafast.co.uk/Downloads/Wiring_Diagrams/S60%20Wiring%20Diagram.pdf
 
S80 ecu:
SDM-500 pin 5 CAN1 HI   yellow  -------------> S80 pin 26 CAN H on plug with two key-ways
SDM-500 pin 4 CAN1 LO  blue     -------------> S80 pin 28 CAN L on plug with two key-ways
http://www.dtafast.co.uk/Downloads/Wiring_Diagrams/S80%20Wiring%20Diagram.pdf
 
S100 ecu:
SDM-500 pin 5 CAN1 HI   yellow  -------------> S100 pin 16 CAN H
SDM-500 pin 4 CAN1 LO  blue     -------------> S100 pin 17 CAN L
http://www.dtafast.co.uk/Downloads/Wiring_Diagrams/S100%20Wiring%20Diagram.pdf
 
 
ECU CONFIGURATION
  • Launch DTASwin PC Software
  • Ensure that the ecu uses at least firmware version V62.01, if not then follow DTA instructions to update the ecu firmware
  • Connect DTASwin to the ecu.
  • Navigate to the "Other Map Settings" menu and select "Data Stream"
  • Change your settings to match the image bellow:
 
 
6. Update ecu and close window.
7. Now you are ready to diplay and record data with your Plex SDM-500.
 
PLEX uSDM-SDM-VMU CONFIGURATION