EMTRON

WIRING
EMtron CANH  >> SDM 300-500 pin 5 CAN1 HI  yellow
EMtron CANL  >> SDM 300-500 pin 4 CAN1 LOW  blue
 
ECU CONFIGURATION
Use the following settings:
Can Bus Speed: 1Mbit
CAN x - CHANNEL 1
Enable: ON
CAN Base Address: 1250
DATA Set: Pre-defined tx Data Set 1
Addressing: Single (11bit)
Direction: Transmit
Transmit Rate : 20Hz(uSDM) / 50Hz(SDM)
 
 
PLEX uSDM-SDM-VMU CONFIGURATION
Set the Can Bus Port Speed to 1Mbit.
Load the EMTRON_Predefined.PlexCanRXConfig configuration file in the Can Receive Setup.