WIRING
Tornado 2 ecu
SDM-500 pin 5 CAN1 HI   yellow  -------------> Tornado connector A, pin 21
SDM-500 pin 4 CAN1 LO  blue     -------------> Tornado connector A, pin 22
http://www.twinkam.co.uk/online/templatemedia/all_lang/resources/Tornado+V3+Wiring+Diagram.pdf
 
Typhoon 2 ecu
SDM-500 pin 5 CAN1 HI   yellow  -------------> Typhoon connector A, pin 21
SDM-500 pin 4 CAN1 LO  blue     -------------> Typhoon connector A, pin 22
http://www.twinkam.co.uk/online/templatemedia/all_lang/resources/Typhoon+V3+Pin-out.pdf
 
 
 
ECU CONFIGURATION
No configuration required. The SC Tornado and Typhoon ecus always broadcast data over the can bus.
 