Configurable Engine Log
Odometer:
The device will keep a record of the distance traveled. The speed signal source is defined in the Functions Setup and by the data channels functions assignments. The odometer value can be set from the Plex Device Manager Software/Data logs/Engine Log.
Trip meters:
The device will keep a record of the distance traveled in 2 separate trip meters. The speed signal source is defined in the Functions Setup and by the data channels functions assignments. The trip meters can be setup to reset on every startup if desired.
Engine Hour Meter
The device will keep a record of operational hours of the engine. The Hour Meter value can be set from the Plex Device Manager Software/Data logs/Engine Log.
Time will be counted only when engine RPM is above 500.
Alarm History:
The device will keep a log of the last 100 alarms that where triggered. If the same alarm type is triggered within 60 seconds of the previous occurrence a new record is not created but the value and time stamp is updated.
Additionally the total active time for each alarm is logged. This information can be viewed and reset from the Plex Device Manager Software/Data logs/Engine Log.
Max Min value log:
The device will keep maximum or minimum value for up to 8 data channels in the Engine Log memory. The engine log values will only be updated when engine RPM is above 500.
Accumulated Condition time log:
The device will keep the total accumulated time for up to 8 flag channels. This feature is useful when combined with the user flags.
Fixed Engine Log
Odometer:
The device will keep a record of the distance traveled. The speed signal source is defined in the Functions Setup and by the data channels functions assignments. The odometer value can be set from the Plex Device Manager Software/Data logs/Engine Log.
Trip meters:
The device will keep a record of the distance traveled in 2 separate trip meters. The speed signal source is defined in the Functions Setup and by the data channels functions assignments. The trip meters can be setup to reset on every startup if desired.
Alarm History:
The device will keep a log of the last 100 alarms that where triggered. If the same alarm type is triggered within 60 seconds of the previous occurrence a new record is not created but the value and time stamp is updated.
Additionally the total active time for each alarm is logged. This information can be viewed and reset from the Plex Device Manager Software/Data logs/Engine Log.
Max Min value log:
The device will keep maximum or minimum value for up to 8 data channels in the Engine Log memory. The engine log values will only be updated when engine RPM is above 500.
For this function to work a data channel must be assigned to the 'RPM' function.